Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
J Med Imaging (Bellingham) ; 10(6): 065501, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37937259

RESUMO

Purpose: To improve segmentation accuracy in head and neck cancer (HNC) radiotherapy treatment planning for the 1.5T hybrid magnetic resonance imaging/linear accelerator (MR-Linac), three-dimensional (3D), T2-weighted, fat-suppressed magnetic resonance imaging sequences were developed and optimized. Approach: After initial testing, spectral attenuated inversion recovery (SPAIR) was chosen as the fat suppression technique. Five candidate SPAIR sequences and a nonsuppressed, T2-weighted sequence were acquired for five HNC patients using a 1.5T MR-Linac. MR physicists identified persistent artifacts in two of the SPAIR sequences, so the remaining three SPAIR sequences were further analyzed. The gross primary tumor volume, metastatic lymph nodes, parotid glands, and pterygoid muscles were delineated using five segmentors. A robust image quality analysis platform was developed to objectively score the SPAIR sequences on the basis of qualitative and quantitative metrics. Results: Sequences were analyzed for the signal-to-noise ratio and the contrast-to-noise ratio and compared with fat and muscle, conspicuity, pairwise distance metrics, and segmentor assessments. In this analysis, the nonsuppressed sequence was inferior to each of the SPAIR sequences for the primary tumor, lymph nodes, and parotid glands, but it was superior for the pterygoid muscles. The SPAIR sequence that received the highest combined score among the analysis categories was recommended to Unity MR-Linac users for HNC radiotherapy treatment planning. Conclusions: Our study led to two developments: an optimized, 3D, T2-weighted, fat-suppressed sequence that can be disseminated to Unity MR-Linac users and a robust image quality analysis pathway that can be used to objectively score SPAIR sequences and can be customized and generalized to any image quality optimization protocol. Improved segmentation accuracy with the proposed SPAIR sequence will potentially lead to improved treatment outcomes and reduced toxicity for patients by maximizing the target coverage and minimizing the radiation exposure of organs at risk.

2.
Brachytherapy ; 22(6): 736-745, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37612174

RESUMO

PURPOSE: To determine the feasibility of quantitative apparent diffusion coefficient (ADC) acquisition during magnetic resonance imaging-guided brachytherapy (MRgBT) using reduced field-of-view (rFOV) diffusion-weighted imaging (DWI). METHODS AND MATERIALS: T2-weighted (T2w) MR and full-FOV single-shot echo planar (ssEPI) DWI were acquired in 7 patients with cervical or vaginal malignancy at baseline and prior to brachytherapy, while rFOV-DWI was acquired during MRgBT following brachytherapy applicator placement. The gross target volume (GTV) was contoured on the T2w images and registered to the ADC map. Voxels at the GTV's maximum Maurer distance comprised a central sub-volume (GTVcenter). Contour ADC mean and standard deviation were compared between timepoints using repeated measures ANOVA. RESULTS: ssEPI-DWI mean ADC increased between baseline and prebrachytherapy from 1.03 ± 0.18 10-3 mm2/s to 1.34 ± 0.28 10-3 mm2/s for the GTV (p = 0.06) and from 0.84 ± 0.13 10-3 mm2/s to 1.26 ± 0.25 10-3 mm2/s at the level of the GTVcenter (p = 0.03), consistent with early treatment response. rFOV-DWI during MRgBT demonstrated mean ADC values of 1.28 ± 0.14 10-3 mm2/s and 1.28 ± 0.19 10-3 mm2/s for the GTV and GTVcenter, respectively (p = 0.02 and p = 0.03 relative to baseline). No significant differences were observed between ssEPI-DWI and rFOV-DWI ADC measurements. CONCLUSIONS: Quantitative ADC measurement in the setting of MRI guided brachytherapy implant placement for cervical and vaginal cancers is feasible using rFOV-DWI, with comparable mean ADC comparable to prebrachytherapy ssEPI-DWI, and may enable MRI-guided radiotherapy targeting of low ADC, radiation resistant sub-volumes of tumor.


Assuntos
Braquiterapia , Neoplasias Vaginais , Feminino , Humanos , Neoplasias Vaginais/diagnóstico por imagem , Neoplasias Vaginais/radioterapia , Braquiterapia/métodos , Estudos de Viabilidade , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
3.
Radiographics ; 42(7): 2112-2130, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36018785

RESUMO

Endometrial cancer is the second most common gynecologic cancer worldwide and the most common gynecologic cancer in the United States, with an increasing incidence in high-income countries. Although the International Federation of Gynecology and Obstetrics (FIGO) staging system for endometrial cancer is a surgical staging system, contemporary published evidence-based data and expert opinions recommend MRI for treatment planning as it provides critical diagnostic information on tumor size and depth, extent of myometrial and cervical invasion, extrauterine extent, and lymph node status, all of which are essential in choosing the most appropriate therapy. Multiparametric MRI using a combination of T2-weighted sequences, diffusion-weighted imaging, and multiphase contrast-enhanced imaging is the mainstay for imaging assessment of endometrial cancer. Identification of important prognostic factors at MRI improves both treatment selection and posttreatment follow-up. MRI also plays a crucial role for fertility-preserving strategies and in patients who are not surgical candidates by helping guide therapy and identify procedural complications. This review is a product of the Society of Abdominal Radiology Uterine and Ovarian Cancer Disease-Focused Panel and reflects a multidisciplinary international collaborative effort to summarize updated information highlighting the role of MRI for endometrial cancer depiction and delineation, treatment planning, and follow-up. The article includes information regarding dedicated MRI protocols, tips for MRI reporting, imaging pitfalls, and strategies for image quality optimization. The roles of MRI-guided radiation therapy, hybrid PET/MRI, and advanced MRI techniques that are applicable to endometrial cancer imaging are also discussed. Online supplemental material is available for this article. ©RSNA, 2022.


Assuntos
Neoplasias do Endométrio , Neoplasias dos Genitais Femininos , Humanos , Feminino , Estadiamento de Neoplasias , Neoplasias do Endométrio/diagnóstico , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/cirurgia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias dos Genitais Femininos/patologia
4.
Brachytherapy ; 21(4): 369-388, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35725550

RESUMO

PURPOSE: To present recommendations for the use of imaging for evaluation and procedural guidance of brachytherapy for cervical cancer patients. METHODS: An expert panel comprised of members of the Society of Abdominal Radiology Uterine and Ovarian Cancer Disease Focused Panel and the American Brachytherapy Society jointly assessed the existing literature and provide data-driven guidance on imaging protocol development, interpretation, and reporting. RESULTS: Image-guidance during applicator implantation reduces rates of uterine perforation by the tandem. Postimplant images may be acquired with radiography, computed tomography (CT), or magnetic resonance imaging (MRI), and CT or MRI are preferred due to a decrease in severe complications. Pre-brachytherapy T2-weighted MRI may be used as a reference for contouring the high-risk clinical target volume (HR-CTV) when CT is used for treatment planning. Reference CT and MRI protocols are provided for reference. CONCLUSIONS: Image-guided brachytherapy in locally advanced cervical cancer is essential for optimal patient management. Various imaging modalities, including orthogonal radiographs, ultrasound, computed tomography, and magnetic resonance imaging, remain integral to the successful execution of image-guided brachytherapy.


Assuntos
Braquiterapia , Radiologia , Neoplasias do Colo do Útero , Braquiterapia/métodos , Consenso , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia
5.
Med Phys ; 48(10): 6051-6059, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34293208

RESUMO

PURPOSE: Dynamic susceptibility contrast (DSC)-MRI is a perfusion imaging technique from which useful quantitative imaging biomarkers can be derived. Relative cerebral blood volume (rCBV) is such a biomarker commonly used for evaluating brain tumors. To account for the extravasation of contrast agents in tumors, post-processing leakage correction is often applied to improve rCBV accuracy. Digital reference objects (DRO) are ideal for testing the post-processing software, because the biophysical model used to generate the DRO can be matched to the one that the software uses. This study aims to develop DROs to validate the leakage correction of software using Weisskoff model and to examine the effect of background signal time curves that are required by the model. METHODS: Three DROs were generated using the Weisskoff model, each composed of nine foreground lesion objects with combinations of different levels of rCBV and contrast leakage parameter (K2). Three types of background were implemented for these DROs: (1) a multi-compartment brain-like background, (2) a sphere background with a constant signal time curve, and (3) a sphere background with signal time curve identical to that of the brain-like DRO's white matter (WM). The DROs were then analyzed with an FDA-cleared software with and without leakage correction. Leakage correction was tested with and without brain segmentation. RESULTS: Accuracy of leakage correction was able to be verified using the brain-like phantom and the sphere phantom with WM background. The sphere with constant background did not perform well with leakage correction with or without brain segmentation. The DROs were able to verify that for the particular software tested, leakage correction with brain segmentation achieved the lowest error. CONCLUSIONS: DSC-MRI DROs with biophysical model matched to that of the post-processing software can be well used for the software's validation, provided that the background signals are also properly simulated for generating the reference time curve required by the model. Care needs to be taken to consider the interaction of the design of the DRO with the software's implementation of brain segmentation to extract the reference time curve.


Assuntos
Neoplasias Encefálicas , Meios de Contraste , Neoplasias Encefálicas/diagnóstico por imagem , Volume Sanguíneo Cerebral , Humanos , Imageamento por Ressonância Magnética , Software
6.
Cancer Imaging ; 21(1): 3, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407861

RESUMO

BACKGROUND: The utility of multiparametric MRI (mpMRI) in detecting suspected local recurrence post radical prostatectomy (RP) may be associated with PSA and Gleason grade. The purpose of the study was to evaluate the likelihood of detecting locally recurrent prostate cancer utilizing mpMRI in patients with suspected recurrence following radical prostatectomy (RP) parsed by PSA and Gleason grade. METHODS: One hundred ninety five patients with suspected local recurrence were imaged on a 1.5 T MRI with torso array and endorectal coil in this retrospective study. mpMRI interpretations were stratified by PSA and lower (Gleason < 7) vs. higher grade tumors (Gleason 8-10). Recursive partitioning was used to determine whether mpMRI interpretations could be classified as positive or negative. RESULTS: The majority of mpMRI interpretations in patients with lower Gleason grade tumors and PSA < 0.5 ng/mL were negative (68/78, 87.2%, p = 0.004). The majority of mpMRI interpretations in patients with higher Gleason grade tumors and PSA > 1.5 ng/mL were positive (8/9, 88.9%, p = 0.003). Findings were corroborated by recursive partitioning, which identified a PSA = 0.5 ng/ml in patients with lower grade tumors and a PSA = 1.5 ng/mL in patients with higher grade tumors as differentiating negative and positive mpMRIs. CONCLUSION: In the setting of suspected recurrence after RP, mpMRI results are associated with PSA and Gleason grade, both of which can help guide when mpMRI may find utility. mpMRI is likely to be low diagnostic yield and negative for recurrence (87%) in the setting of lower Gleason grade tumors and PSA < 0.5 ng/mL. mpMRI is likely to be of low diagnostic value and positive for recurrence (89%) in the setting of PSA > 1.5 ng/mL and higher grade tumors; in this case, mpMRI findings may be more useful for directing biopsy and local therapy. Between these extremes, PSA > 0.5 ng/mL and lower grade tumors or PSA < 1.5 ng/mL and higher grade tumors, mpMRI results are less predictable, suggesting greater diagnostic value for detecting recurrence post prostatectomy.


Assuntos
Calicreínas/sangue , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Recidiva Local de Neoplasia/sangue , Recidiva Local de Neoplasia/patologia , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
7.
Int J Radiat Oncol Biol Phys ; 108(5): 1319-1328, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32712257

RESUMO

PURPOSE: We aim to characterize the quantitative dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) parameters associated with advanced mandibular osteoradionecrosis (ORN) compared with the contralateral normal mandible. METHODS AND MATERIALS: Patients with a diagnosis of advanced ORN after curative-intent radiation treatment of head and neck cancer were prospectively enrolled after institutional review board approval and study-specific informed consent were obtained. Quantitative maps generated with the Tofts and extended Tofts pharmacokinetic models were used for analysis. Manual segmentation of advanced ORN 3-dimensional volume was done using anatomic sequences to create ORN volumes of interest (VOIs). Subsequently, normal mandibular VOIs were segmented on the contralateral healthy mandible of similar volume and anatomic location to create control VOIs. Finally, anatomic sequences were coregistered to DCE sequences, and contours were propagated to the respective parameter maps. RESULTS: Thirty patients were included. The median time to ORN diagnosis after completion of IMRT was 38 months (range, 6-184 months), whereas median time to ORN progression to advanced grade after initial diagnosis was 5.6 months (range, 0-128 months). There were statistically significant higher Ktrans and Ve in ORN-VOIs compared with controls (0.23 vs 0.07 min-1, and 0.34 vs 0.15; P < .0001 for both). The average relative increase of Ktrans in ORN-VOIs was 3.2-fold higher than healthy mandibular control VOIs. Moreover, the corresponding rise of Ve in ORN-VOIs was 2.7-fold higher than in the controls. Using combined Ktrans and Ve parameters, 27 patients (90%) had at least a 200% increase of either of the studied parameters in the ORN-VOIs compared with their healthy mandible VOIs. CONCLUSIONS: Our results confirm that there is a quantitatively significant higher degree of leakiness in the mandibular vasculature as measured using DCE-MRI parameters of areas with advanced ORN versus healthy mandible.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Mandíbula/diagnóstico por imagem , Doenças Mandibulares/diagnóstico por imagem , Osteorradionecrose/diagnóstico por imagem , Adulto , Idoso , Vasos Sanguíneos/efeitos da radiação , Fracionamento da Dose de Radiação , Feminino , Neoplasias de Cabeça e Pescoço/irrigação sanguínea , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Mandíbula/irrigação sanguínea , Doenças Mandibulares/patologia , Pessoa de Meia-Idade , Osteorradionecrose/patologia , Estudos Prospectivos , Lesões por Radiação , Radioterapia de Intensidade Modulada/efeitos adversos , Carcinoma de Células Escamosas de Cabeça e Pescoço/irrigação sanguínea , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Estatísticas não Paramétricas , Fatores de Tempo , Adulto Jovem
8.
Int J Hyperthermia ; 37(1): 356-365, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32308071

RESUMO

Background: Thermoembolization presents a unique treatment alternative for patients diagnosed with hepatocellular carcinoma. The approach delivers a reagent that undergoes an exothermic chemical reaction and combines the benefits of embolic as well as thermal- and chemical-ablative therapy modalities. The target tissue and vascular bed are subjected to simultaneous hyperthermia, ischemia, and chemical denaturation in a single procedure. To guide optimal delivery, we developed a mathematical model for understanding the competing diffusive and convective effects observed in thermoembolization delivery protocols.Methods: A mixture theory formulation was used to mathematically model thermoembolization as chemically reacting transport of an electrophile, dichloroacetyl chloride (DCACl), within porous living tissue. Mass and energy transport of each relevant constituent are considered. Specifically, DCACl is injected into the vessels and exothermically reacts with water in the blood or tissue to form dichloroacetic acid and hydrochloric acid. Neutralization reactions are assumed instantaneous in this approach. We validated the mathematical model predictions of temperature using MR thermometry of the thermoembolization procedure performed in ex vivo kidney.Results: Mathematical modeling predictions of tissue death were highly dependent on the vascular geometry, injection pressure, and intrinsic amount of exothermic energy released from the chemical species, and were able to recapitulate the temperature distributions observed in MR thermometry.Conclusion: These efforts present a first step toward formalizing a mathematical model for thermoembolization and are promising for providing insight for delivery protocol optimization. While our approach captured the observed experimental temperature measurements, larger-scale experimental validation is needed to prioritize additional model complexity and fidelity.


Assuntos
Embolização Terapêutica/métodos , Modelos Teóricos , Humanos
9.
Brachytherapy ; 19(3): 305-315, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32265119

RESUMO

PURPOSE: The purpose of this study was to investigate the utility of a novel MRI-positive line marker, composed of C4:S (cobalt chloride-based contrast agent) encapsulated in high-density polyethylene tubing, in permitting dosimetry and treatment planning directly on MRI. METHODS AND MATERIALS: We evaluated the clinical feasibility of the C4:S line markers in nine sequential brachytherapy procedures for gynecologic malignancies, including six tandem-and-ovoid and three interstitial cases. We then quantified the internal resource utilization of an intraoperative MRI-guided procedural episode via time-driven activity-based costing, identifying opportunities for cost-containment with use of the C4:S line markers. RESULTS: The C4:S line markers demonstrated the strongest positive signal visibility on 3D constructive interference in steady state (CISS)/FIESTA-C followed by T1-weighted sequences, permitting accurate delineation of the applicator lumen and thus the source path. These images may be fused along with traditional T2-weighted sequences for optimal tumor and anatomy contouring, followed by treatment planning directly on MRI. By eliminating postoperative CT for fusion and applicator registration from the procedural episode, use of the C4:S line markers could decrease workflow time and lower total delivery costs per procedure. CONCLUSIONS: This analysis supports the clinical utility and value contribution of the C4:S line markers, which permit accurate MRI-based dosimetry and treatment planning, thereby eliminating the need for postoperative CT for fusion and applicator registration.


Assuntos
Braquiterapia , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Neoplasias dos Genitais Femininos/radioterapia , Imageamento por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia/economia , Cobalto , Meios de Contraste , Controle de Custos , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/economia
10.
Neurosurgery ; 87(1): 112-122, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31539421

RESUMO

BACKGROUND: Laser Interstitial Thermal Therapy (LITT) has been used to treat recurrent brain metastasis after stereotactic radiosurgery (SRS). Little is known about how best to assess the efficacy of treatment, specifically the ability of LITT to control local tumor progression post-SRS. OBJECTIVE: To evaluate the predictive factors associated with local recurrence after LITT. METHODS: Retrospective study with consecutive patients with brain metastases treated with LITT. Based on radiological aspects, lesions were divided into progressive disease after SRS (recurrence or radiation necrosis) and new lesions. Primary endpoint was time to local recurrence. RESULTS: A total of 61 consecutive patients with 82 lesions (5 newly diagnosed, 46 recurrence, and 31 radiation necrosis). Freedom from local recurrence at 6 mo was 69.6%, 59.4% at 12, and 54.7% at 18 and 24 mo. Incompletely ablated lesions had a shorter median time for local recurrence (P < .001). Larger lesions (>6 cc) had shorter time for local recurrence (P = .03). Dural-based lesions showed a shorter time to local recurrence (P = .01). Tumor recurrence/newly diagnosed had shorter time to local recurrence when compared to RN lesions (P = .01). Patients receiving systemic therapy after LITT had longer time to local recurrence (P = .01). In multivariate Cox-regression model, the HR for incomplete ablated lesions was 4.88 (P < .001), 3.12 (P = .03) for recurrent tumors, and 2.56 (P = .02) for patients not receiving systemic therapy after LITT. Complication rate was 26.2%. CONCLUSION: Incompletely ablated and recurrent tumoral lesions were associated with higher risk of treatment failure and were the major predicting factors for local recurrence. Systemic therapy after LITT was a protective factor regarding local recurrence.


Assuntos
Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/terapia , Terapia a Laser/tendências , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/terapia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Hipertermia Induzida/efeitos adversos , Hipertermia Induzida/tendências , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Lesões por Radiação/diagnóstico , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
11.
Brachytherapy ; 19(4): 427-437, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31786169

RESUMO

PURPOSE: We integrated a brachytherapy procedural workflow within an existing diagnostic 3.0-T (3T) MRI suite. This setup facilitates intraoperative MRI guidance for optimal applicator positioning, particularly for interstitial needle placements in gynecologic cases with extensive parametrial involvement. METHODS AND MATERIALS: Here we summarize the multidisciplinary collaboration, equipment, and supplies necessary to implement an intraoperative MRI-guided brachytherapy program; outline the operational workflow via process maps; and address safety precautions. We evaluate internal resource utilization associated with this progressive approach via time-driven activity-based costing methodology, comparing institutional costs to that of a traditional workflow (within a CT suite, followed by separate postprocedure MRI) over a single brachytherapy procedural episode. RESULTS: Resource utilization was only 15% higher for the intraoperative MRI-based workflow, attributable to use of the MRI suite and increased radiologist effort. Personnel expenses were the greatest cost drivers for either workflow, accounting for 76-77% of total resource utilization. However, use of the MRI suite allows for potential cost-shifting opportunities from other resources, such as CT, during the procedural episode. Improvements in process speed can also decrease costs: for each 10% decrease in case duration from baseline procedure time, total costs could decrease by roughly 8%. CONCLUSIONS: This analysis supports the feasibility of an intraoperative MRI-guided brachytherapy program within a diagnostic MRI suite and defines many of the resources required for this procedural workflow. Longer followup will define the full utility of this approach in optimizing the therapeutic ratio for gynecologic cancers, which may translate into lower costs and higher value with time, over a full cycle of care.


Assuntos
Braquiterapia/economia , Braquiterapia/métodos , Neoplasias dos Genitais Femininos/radioterapia , Custos de Cuidados de Saúde , Imageamento por Ressonância Magnética , Radiologia Intervencionista/organização & administração , Feminino , Neoplasias dos Genitais Femininos/cirurgia , Pessoal de Saúde/economia , Recursos em Saúde/economia , Recursos em Saúde/estatística & dados numéricos , Humanos , Período Intraoperatório , Imageamento por Ressonância Magnética/economia , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X/economia , Fluxo de Trabalho
12.
PLoS One ; 14(9): e0221877, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31487307

RESUMO

Radiomics studies require large patient cohorts, which often include patients imaged using different imaging protocols. We aimed to determine the impact of variability in imaging protocol parameters and interscanner variability using a phantom that produced feature values similar to those of patients. Positron emission tomography (PET) scans of a Hoffman brain phantom were acquired on GE Discovery 710, Siemens mCT, and Philips Vereos scanners. A standard-protocol scan was acquired on each machine, and then each parameter that could be changed was altered individually. The phantom was contoured with 10 regions of interest (ROIs). Values for 45 features with 2 different preprocessing techniques were extracted for each image. To determine the impact of each parameter on the reliability of each radiomics feature, the intraclass correlation coefficient (ICC) was calculated with the ROIs as the subjects and the parameter values as the raters. For interscanner comparisons, we compared the standard deviation of each radiomics feature value from the standard-protocol images to the standard deviation of the same radiomics feature from PET scans of 224 patients with non-small cell lung cancer. When the pixel size was resampled prior to feature extraction, all features had good reliability (ICC > 0.75) for the field of view and matrix size. The time per bed position had excellent reliability (ICC > 0.9) on all features. When the filter cutoff was restricted to values below 6 mm, all features had good reliability. Similarly, when subsets and iterations were restricted to reasonable values used in clinics, almost all features had good reliability. The average ratio of the standard deviation of features on the phantom scans to that of the NSCLC patient scans was 0.73 using fixed-bin-width preprocessing and 0.92 using 64-level preprocessing. Most radiomics feature values had at least good reliability when imaging protocol parameters were within clinically used ranges. However, interscanner variability was about equal to interpatient variability; therefore, caution must be used when combining patients scanned on equipment from different vendors in radiomics data sets.


Assuntos
Algoritmos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Compostos Radiofarmacêuticos , Estudos Retrospectivos
13.
Radiographics ; 39(5): 1476-1500, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31498740

RESUMO

Locally advanced human papillomavirus (HPV)-associated gynecologic cancers, including cervical, vaginal, and vulvar cancers, are treated primarily with radiation therapy (RT). Cervical cancer remains a leading cause of cancer death among women worldwide. The superior soft-tissue resolution of MRI compared with other imaging modalities makes it an ideal modality for RT planning, execution, and follow-up of these malignancies. This superiority has been corroborated in the literature when comparing MRI-based RT planning to radiography-based conventional treatment planning approaches. In 2005, the Groupe Européen de Curiethérapie and the European Society for Radiation Therapy and Oncology guidelines underscored the central role of MRI for successful implementation of three-dimensional image-based cervical cancer brachytherapy. The delineation of both gross tumor volume and clinical tumor volume for brachytherapy is performed at the time of each brachytherapy application, on the basis of the findings depicted on anatomic MR images. Contemporary knowledge concerning the role of MRI for RT planning in HPV-associated gynecologic cancers warrants an understanding of the epidemiology and clinical manifestations of these cancers, as well as knowledge of MRI protocol for cancer staging, selection of RT candidates, brachytherapy implant assessment, posttreatment surveillance, and delineation of treatment-related complications. Technical requirements, patient preparation, and image acquisition protocols are detailed in this review, and imaging-based treatment protocols are summarized. Knowledge of these fundamental concepts enables the radiologist to play an important role in diagnosis, staging, and posttreatment follow-up, helping to guide radiation oncologists and other clinicians in the management of these malignancies.©RSNA, 2019.


Assuntos
Braquiterapia/métodos , Neoplasias dos Genitais Femininos , Imageamento por Ressonância Magnética/métodos , Infecções por Papillomavirus , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Neoplasias dos Genitais Femininos/radioterapia , Neoplasias dos Genitais Femininos/virologia , Humanos , Infecções por Papillomavirus/diagnóstico por imagem , Infecções por Papillomavirus/radioterapia , Infecções por Papillomavirus/virologia
14.
PLoS One ; 14(9): e0222509, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31536526

RESUMO

Radiomics studies require many patients in order to power them, thus patients are often combined from different institutions and using different imaging protocols. Various studies have shown that imaging protocols affect radiomics feature values. We examined whether using data from cohorts with controlled imaging protocols improved patient outcome models. We retrospectively reviewed 726 CT and 686 PET images from head and neck cancer patients, who were divided into training or independent testing cohorts. For each patient, radiomics features with different preprocessing were calculated and two clinical variables-HPV status and tumor volume-were also included. A Cox proportional hazards model was built on the training data by using bootstrapped Lasso regression to predict overall survival. The effect of controlled imaging protocols on model performance was evaluated by subsetting the original training and independent testing cohorts to include only patients whose images were obtained using the same imaging protocol and vendor. Tumor volume, HPV status, and two radiomics covariates were selected for the CT model, resulting in an AUC of 0.72. However, volume alone produced a higher AUC, whereas adding radiomics features reduced the AUC. HPV status and one radiomics feature were selected as covariates for the PET model, resulting in an AUC of 0.59, but neither covariate was significantly associated with survival. Limiting the training and independent testing to patients with the same imaging protocol reduced the AUC for CT patients to 0.55, and no covariates were selected for PET patients. Radiomics features were not consistently associated with survival in CT or PET images of head and neck patients, even within patients with the same imaging protocol.


Assuntos
Neoplasias de Cabeça e Pescoço/mortalidade , Neoplasias de Cabeça e Pescoço/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
15.
Int J Hyperthermia ; 36(1): 730-738, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31362538

RESUMO

Purpose: MR temperature imaging (MRTI) was employed for visualizing the spatiotemporal evolution of the exotherm of thermoembolization, an investigative transarterial treatment for solid tumors. Materials and methods: Five explanted kidneys were injected with thermoembolic solutions, and monitored by MRTI. In three nonselective experiments, 5 ml of 4 mol/l dichloroacetyl chloride (DCA-Cl) solution in a hydrocarbon vehicle was injected via the main renal artery. For two of these three, MRTI temperature data were compared to fiber optic thermal probes. Another two kidneys received selective injections, treating only portions of the kidneys with 1 ml of 2 mol/l DCA-Cl. MRTI data were acquired and compared to changes in pre- and post-injection CT. Specimens were bisected and photographed for gross pathology 24 h post-procedure. Results: MRTI temperature estimates were within ±1 °C of the probes. In experiments without probes, MRTI measured increases of 30 °C. Some regions had not reached peak temperature by the end of the >18 min acquisition. MRTI indicated the initial heating occurred in the renal cortex, gradually spreading more proximally toward the main renal artery. Gross pathology showed the nonselective injection denatured the entire kidney whereas in the selective injections, only the treated territory was coagulated. Conclusion: The spatiotemporal evolution of thermoembolization was visualized for the first time using noninvasive MRTI, providing unique insight into the thermodynamics of thermoembolization. Précis Thermoembolization is being investigated as a novel transarterial treatment. In order to begin to characterize delivery of this novel treatment modality and aid translation from the laboratory to patients, we employ MR temperature imaging to visualize the spatiotemporal distribution of temperature from thermoembolization in ex vivo tissue.


Assuntos
Embolização Terapêutica , Imageamento por Ressonância Magnética , Termografia , Animais , Rim/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Suínos , Temperatura
17.
J Neurooncol ; 141(2): 475, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30635762

RESUMO

The original article was published with an incorrect protocol number. The correct protocol number is DR07-0585.

18.
Comput Med Imaging Graph ; 69: 134-139, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30268005

RESUMO

Radiomics studies have demonstrated the potential use of quantitative image features to improve prognostic stratification of patients with head and neck cancer. Imaging protocol parameters that can affect radiomics feature values have been investigated, but the effects of artifacts caused by intrinsic patient factors have not. Two such artifacts that are common in patients with head and neck cancer are streak artifacts caused by dental fillings and beam-hardening artifacts caused by bone. The purpose of this study was to test the impact of these artifacts and if needed, methods for compensating for these artifacts in head and neck radiomics studies. The robustness of feature values was tested by removing slices of the gross tumor volume (GTV) on computed tomography images from 30 patients with head and neck cancer; these images did not have streak artifacts or had artifacts far from the GTV. The range of each feature value over a percentage of the GTV was compared to the inter-patient variability at full volume. To determine the effects of beam-hardening artifacts, we scanned a phantom with 5 cartridges of different materials encased in polystyrene buildup. A cylindrical hole through the cartridges contained either a rod of polylactic acid to simulate water or a rod of polyvinyl chloride to simulate bone. A region of interest was drawn in each cartridge flush with the rod. Most features were robust with up to 50% of the original GTV removed. Most feature values did not significantly differ when measured with the polylactic acid rod or the polyvinyl chloride rod. Of those that did, the size of the difference did not exceed the inter-patient standard deviation in most cases. We conclude that simply removing slices affected by streak artifacts can enable these scans to be included in radiomics studies and that contours of structures can abut bone without being affected by beam hardening if needed.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
19.
Sci Rep ; 8(1): 13047, 2018 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-30158540

RESUMO

Radiomics has shown promise in improving models for predicting patient outcomes. However, to maximize the information gain of the radiomics features, especially in larger patient cohorts, the variability in radiomics features owing to differences between scanners and scanning protocols must be accounted for. To this aim, the imaging variability of radiomics feature values was evaluated on 100 computed tomography scanners at 35 clinics by imaging a radiomics phantom using a controlled protocol and the commonly used chest and head protocols of the local clinic. We used a linear mixed-effects model to determine the degree to which the manufacturer and individual scanners contribute to the overall variability. Using a controlled protocol reduced the overall variability by 57% and 52% compared to the local chest and head protocols respectively. The controlled protocol also reduced the relative contribution of the manufacturer to the total variability. For almost all variabilities (manufacturer, scanner, and residual with different preprocesssing), the controlled protocol scans had a significantly smaller variability than the local protocol scans did. For most radiomics features, the imaging variability was small relative to the inter-patient feature variability in non-small cell lung cancer and head and neck squamous cell carcinoma patient cohorts. From this study, we conclude that using controlled scans can reduce the variability in radiomics features, and our results demonstrate the importance of using controlled protocols in prospective radiomics studies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/instrumentação
20.
Med Phys ; 2018 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-30007075

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) provides noninvasive evaluation of patient's anatomy without using ionizing radiation. Due to this and the high soft-tissue contrast, MRI use has increased and has potential for use in longitudinal studies where changes in patients' anatomy or tumors at different time points are compared. Deformable image registration can be useful for these studies. Here, we describe two datasets that can be used to evaluate the registration accuracy of systems for MR images, as it cannot be assumed to be the same as that measured on CT images. ACQUISITION AND VALIDATION METHODS: Two sets of images were created to test registration accuracy. (a) A porcine phantom was created by placing ten 0.35-mm gold markers into porcine meat. The porcine phantom was immobilized in a plastic container with movable dividers. T1-weighted, T2-weighted, and CT images were acquired with the porcine phantom compressed in four different ways. The markers were not visible on the MR images, due to the selected voxel size, so they did not interfere with the measured registration accuracy, while the markers were visible on the CT images and were used to identify the known deformation between positions. (b) Synthetic images were created using 28 head and neck squamous cell carcinoma patients who had MR scans pre-, mid-, and postradiotherapy treatment. An inter- and intrapatient variation model was created using these patient scans. Four synthetic pretreatment images were created using the interpatient model, and four synthetic post-treatment images were created for each of the pretreatment images using the intrapatient model. DATA FORMAT AND USAGE NOTES: The T1-weighted, T2-weighted, and CT scans of the porcine phantom in the four positions are provided. Four T1-weighted synthetic pretreatment images each with four synthetic post-treatment images, and four T2-weighted synthetic pretreatment images each with four synthetic post-treatment images are provided. Additionally, the applied deformation vector fields to generate the synthetic post-treatment images are provided. The data are available on TCIA under the collection MRI-DIR. POTENTIAL APPLICATIONS: The proposed database provides two sets of images (one acquired and one computer generated) for use in evaluating deformable image registration accuracy. T1- and T2-weighted images are available for each technique as the different image contrast in the two types of images may impact the registration accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...